리퍼비시 계측기

리퍼비시 계측기

N9030A 550 EXM P50

  • Model
  • MakerKeysight
  • DescriptionPXA Signal Analyzer, 3Hz-50GHz
  • Option550 EXM LNP MPB P50
  • Rental문의요망
  • Stock문의요망

Functionality

Performance

  • ±0.19 dB absolute amplitude accuracy
  • +22 dBm third order intercept (TOI)
  • -172 dBm displayed average noise level (DANL) with preamplifier and noise floor extension
  • -83 dB (-88 dB nominal) W-CDMA ACLR dynamic range (with noise correction on)

Measurement Applications & Software

  • PXA supports over 25 measurement applications, covering cellular communication, wireless connectivity, digital video, and general purpose.
  • Advanced analysis of more than 70 signal formats; software runs inside the PXA.
  • MATLAB data analysis software for general purpose data analysis, visualization, and measurement automation.
  • Agilent’s PowerSuite one-button power measurements included as standard

Automation & Communication Interface

  • LXI class C compliant, SCPI and IVI-COM
  • USB 2.0, 1000Base-T LAN, GPIB
  • Programming remote language compatibility with PSA, 8566/68, 856x, and more
  • Common X-Series user interface/Open Windows® XP operating system

The PXA signal analyzer is the highest-performance member of the X-Series and is the evolutionary replacement for your current performance signal analyzer. It provides frequency coverage up to 50 GHz and ensures present and future flexibility through optional measurement capabilities and hardware expandability. Through external mixing with Agilent or third-party harmonic mixers, the PXA can measure signals to 325 GHz and beyond. The PXA’s advanced performance, flexibility, capability, and expandability enable you to address demanding applications in aerospace, defense, commercial communications and more. In addition, the PXA includes extensive remote language compatibility features that make it easier to replace existing Agilent performance spectrum analyzers.

With the performance and flexibility of the PXA, you’ll be equipped to create state-of-the-art original designs. Unravel complex signals through the PXA’s broad set of measurement applications and demodulation capabilities, such as the Keysight 89600 VSA software and MATLAB. Adding real-time spectrum analyzer capabilities is an upgradable option for new and existing PXAs, enabling you to see, capture and understand fleeting, close-in signals at very low levels.

The PXA is ideally suited for high-performance R&D applications in aerospace & defense and commercial wireless communications. The PXA analyzes signals over wider bandwidths, reduces measurement uncertainty and reveals previously hidden signals with Noise Floor Extension.

NFE technology provides a dramatic improvement in the PXA’s ability to accurately measure low-level signals approaching the theoretical “kTB” noise floor. NFE reduces the measurement noise by up to 10 dB and more. With increased averaging, the PXA’s effective noise floor can be extended by up to 10 dB because 90% or more of the contributed noise power is predictable, which means it can be measured, calibrated and then eliminated during normal measurements.

Even at the extremes of signal analysis, your high-performance analyzer should be ready for anything. That’s why we offer real-time spectrum analysis as an upgradable option for new and existing PXAs. With real-time spectrum analyzer capabilities, the PXA offers the widest analysis bandwidth and dynamic range to ensure maximum probability of intercept (POI). And for even deeper analysis and thorough characterization of complex signals, a real-time PXA can also be equipped with the Keysight 89600 VSA software. See, capture and understand the most elusive signals—known or unknown.

  • Detect signals with 100% POI with durations as short as 3.57 µs
  • Scan wide spans of spectrum with 160 MHz real-time bandwidth up to 50 GHz frequency range
  • See small signals in the presence of large ones with up to 75 dB of spurious-free dynamic range 

Every PXA also includes I/Q analyzer functionality and Keysight PowerSuite. It allows viewing of magnitude, phase, or I/Q behavior for complex modulated signals over the maximum available analysis bandwidth. PowerSuite provides a wealth of one-button, standards-based power measurements such as TOI, harmonic distortion and burst power.

  • 3 Hz to 50 GHz
  • 10 MHz (standard), 25, 40 or 140 MHz analysis bandwidth
  • plus/-0.19 dB absolute amplitude accuracy
  • 20 dBm third order intercept (TOI)
  • -172 dBm displayed average noise level (DANL)
  • -83 dBc W-CDMA ACLR dynamic range (with noise correction on)
  • LXI class C compliant, SCPI and IVI-COM
  • USB 2.0, 1000Base-T LAN, GPIB
Options
205 Basic VSA-lite
235 Pre-amplifier
333 X-Series analyzer connectivity
3FP Amplitude correction and limit lines
4FP TOI and harmonics
503 9 kHz to 3.0 GHz Frequency Range
507 Frequency range, 9 kHz to 7.0 GHz
513 Frequency range, 10 Hz to 13.6 GHz
526 20 Hz to 26.5 GHz
550 Frequency range, 3 Hz to 50 GHz
5FP ACP 18 Carrier
6FP TV Trigger and IQ Analyzer
AYA Vector modulation analysis
B1X Increase analysis bandwidth from 10/25 to 160 MHz
B25 25MHz Maximum bandwidth
B40 40MHz Maximum bandwidth
BBA Baseband Analog I/Q
CRP Arbitrary IF output
DP2 Digital processor with 2 GB capture memory
EA3 Electronic attenuator (Frequency range 20 Hz to 3.6 GHz)
EDP Enhanced display package
EMC Basic precompliance EMI features
EP1 Enhanced Phase Noise Performance
EP3 Enhanced phase noise
EP4 Enhanced phase noise performance, CXA
ESC External source control
FS1 Fast sweep capability
FSA Mechanical attenuator, 2 dB steps, 0 to 70 dB
LFE Low Frequency Enabled (allows frequency range to 3 Hz)
LNP Low noise path
LOT 747242 PC6, SSD, W10, 526, B25, EMC, FS1, N9060A-2FP, N9060A-3FP, N9060A-4FP, N9060A-5FP, N9060A-6FP, N9060A-7FP, N9068A-2FP, N9068A-CFP, N9069A-AFP
LOT 772664 550, DP2, EA3, EP1, FS1, FSA, LFE, LNP, MPB, NFE, NUL, P50, DFR, RTL, N9060A-2FP, N9060A-3FP, N9060A-4FP, N9060A-5FP, N9060A-6FP, N9060A-7FP, N9068A-AFP, N9068A-CFP, N9069A-AFP
LOT 773641 526, DP2, EA3, EP1, FS1, FSA, LFE, LNP, NFE, NUL, P26, PFR, RTL, N9060A-3FP, N9060A-4FP, N9060A-5FP, N9060A-6FP, N9060A-7FP, N9060B-2FP, N9063A-AFP, N9068A-AFP
LOT 775792 526,ALV,BIX,BIY,B25,B40,DP2,EA3,EMC,EP1,FS1,FSA,FT2,LFE,LNP,MPB,NFE,NUL,P26,PFR,RT2,RTL,YAV, N9060A: 3 to 7FP, N9060B: 2FP, N9068A: CFP, N9071A: CFP, N9073A: A to EFP, N9079A: CFP
LOT 778754 N9060A 2FP, 3FP, 4FP, N9068A 2FP, N9071A 2XFP, 3,XFP, N9072A 2FP, N9073A 1FP, 2FP, 3FP, N9076A 1FP, N9080A 1FP
MPB Microwave preselector bypass
N9020A-B25 Analysis bandwidth, 25 MHz
N9060A 2 TO 7 FP 2FP Spectrum Analyzer Measurement, 3FP Amplitude Correction and Limit Lines, 4FP TOI and Harmonics, 5FP ACP 18 Carrier, 6FP TV Trigger and IQ Analyzer Enhancement, 7FP Zero Span, Register, Trace, and Spurious Enhancements
N9060A-2FP Spectrum Analyzer Measurement Application
N9060A-3FP Amplitude correction and Limit Lines
N9060A-4FP TOI and Harmonics
N9060A2-4FP TOI and Harmonics
N9060A2FP Spectrum Analyzer Measurement Application
N9060B2FR Spectrum Analyzer Measurement Application
N9073A-1FP Standard-based, one-button W-CDMA measurements; supports analog baseband analysis with Option BBA (BBIQ inputs)
N9073A-2FP Adds HSPA measurements; requires 1FP/1TP
N9075A-2FP Standard-based, one-button Mobile WiMAX measurements; supports analog baseband analysis with Option BBA (BBIQ inputs)
NFE Noise Floor Extension
NUL LO/IM nulling, Minimizes the LO feed-thru and intermodulation distortion
P03 Preamplifier, 100 kHz to 3.6 GHz
P08 8.4 GHz Preamplifier
P50 Preamplifier, 50 GHz
PC4 Upgrade to dual core processor with removable solid state drive
PC5 Single core 64-bit performance processor, 4GB RAM, removable SSD
PFR Precision frequency reference 10 MHz
PLUS Includes: N9060A 3 TO 7FP, N9068A 2FP, N9069A 1 AND 2FP, N9071A 2 AND 3FP, N9072A 2FP AND 2TP, N9073A 1FP, 1TP, 2 AND 3 FP, A TO DFP, N9075A 2FP, N9076A 1FP, N9077A 2FP, N9079A 1 AND 2FP, N9080A 1FP, N9082A 1FP
PRC Portable configuration
RTL Real-time link
T03 9 kHz to 3 GHz Tracking Generator Frequency
YAS Y-axis screen video output

    회사명

    부서명

    구매문의판매문의렌탈문의수리문의교정문의

    전화상담방문상담견적서상담

    문의 및 요청내용 *


    개인정보 수집, 이용 및 처리방침

    - 수집항목: 이름, 연락처, 이메일, 주소
    - 수집/이용목적: 견적요청에 대한 접수 및 결과 회신
    - 이용기간: 원칙적으로 개인정보 수집 및 이용목적이 달성된 후에는 해당 정보를 지체 없이 파기합니다.
    단, 관계법령의 규정에 의하여 보전할 필요가 있는 경우 일정기간 동안 개인정보를 보관할 수 있습니다.

    그 밖의 사항은 (주)누비콤 개인정보취급방침을 준수하며 견적서를 요청하면 개인정보처리방침에 동의하는 것으로 간주됩니다.

    • 개인정보처리방침에 동의합니다.