8720D-012-085

  • Model8720D
  • MakerHP
  • Description50MHz-20Ghz, Network Analyzer
  • Option012 085
  • Rental문의요망
  • Stock문의요망

Keysight (formerly Agilent)  8720D Microwave Vector Network Analyzer 50 MHz to

8720D Microwave Vector Network Analyzer 50 MHz to 13.5, 20, or 40 GHz frequency coverage Key Features & Specifications: 50 MHz to 13.5, 20, or 40 GHz frequency coverage New processor makes measurements and data transfers up to seven times faster Fast-sweeping, built-in synthesized source Integrated solid-state switching S-parameter test set Vecter receiver, error correcton, time domain Up to 105 dB dynamic range Options:Option 010 time domain
Refurbished

  • Alternative N5230A PNA-L Network Analyzer (Option 220/225)
    • Instrument Type : Vector
    • Low end frequency limit : 50 MHz
    • High End Frequency Limit : 20 GHz
    • Output Power Range : 75 dB
    • Input Noise Level <-55dBc @phase noise tp 6- kHz from carrier at 2 GHz; <-35 dBc from carrier at 20 GHz
  • Status Discontinued by Manufacture
  • 50 MHz to 13.5, 20, or 40 GHz frequency coverage
  • New processor makes measurements and data transfers up to seven times faster
  • Fast-sweeping, built-in synthesized source
  • Integrated solid-state switching S-parameter test set
  • Vect0r receiver, error correcton, time domain
  • Up to 105 dB dynamic range

Option 085, high power system
This option is designed to permit the measurement of high power amplifiers at RF levels up to 20 Watts
(+43 dBm), with full two-port calibration. A switch is added to the reference path so that booster
amplifier response can be ratioed out. To protect the analyzer from high power levels, this option
allows the addition of isolators at both test ports and includes internally controlled step attenuators
between couplers and samplers. Bias tees, isolators and booster amplifiers are not included. Network
analyzers with option 085 can also be configured to operate as standard instruments with degraded
power accuracy or as instruments capable of making single connection multiple measurements.

Option 012, direct access receiver configuration
This option provides front panel access to the A and B samplers for improved receiver sensitivity.
Option 012 improves signal-to-noise in free space materials measurements with the use of multiple
antennas. Direct connection of the reflection antennas to the A and B samplers eliminates internal reflections of the transmitted signal in the
reflection path, improving the signal to noise ratio. Option 012 also allows you to add attenuators
between the couplers and samplers, increasing the power handling capability of the instrument.

 

    회사명

    부서명

    구매문의판매문의렌탈문의수리문의교정문의

    전화상담방문상담견적서상담

    문의 및 요청내용 *


    개인정보 수집, 이용 및 처리방침

    - 수집항목: 이름, 연락처, 이메일, 주소
    - 수집/이용목적: 견적요청에 대한 접수 및 결과 회신
    - 이용기간: 원칙적으로 개인정보 수집 및 이용목적이 달성된 후에는 해당 정보를 지체 없이 파기합니다.
    단, 관계법령의 규정에 의하여 보전할 필요가 있는 경우 일정기간 동안 개인정보를 보관할 수 있습니다.

    그 밖의 사항은 (주)누비콤 개인정보취급방침을 준수하며 견적서를 요청하면 개인정보처리방침에 동의하는 것으로 간주됩니다.

    • 개인정보처리방침에 동의합니다.